To Set Up Connections to Use Public DNS (Domain Name System)
You must complete this procedure if the Secure Connection feature is enabled during the ConstructSim Planner installation.
-
Open eB System Management Console ( ).
- In the Explorer pane, under the Servers node, navigate to . A diagram displays in the right pane, showing the connection between the client and the server.
- Double-click the arrow that connects the client and server. The Connection Properties dialog opens.
- In the Connection Info field, remove the name of the default machine and enter the public DNS.
- Click OK in the Connections Properties dialog.
To Turn on the Work Queue Service to Run on the Data Processing Server
- Open eB System Management Console and navigate to the data processing server.
- Configure the work queue service for the data processing server.